Home
Archives |
Cheryl's List #123 -
May 14, 2008
 |
Welcome to Cheryl's List!
If you obtained this from someone else and would like your own FREE copy
of Cheryl's List in the future, see the information at the end of this
email.
1. Important APARs
2. Request for More SMF Information
3. Status of Tuning Letter
2008 No. 2
1. Important APARs
Here are some APARs that I think
are important:
-
Ken Williams, an independent
consultant for CPT Global, pointed out a new OPEN APAR (5May2008), that
I think is important because of the large number of lost MIPS that can
be involved. Here’s his email:
Here’s an unsolved APAR without
a PTF that your readers might want to be aware of - it hit us hard here
and could be worth more than 250 MIPS in our busiest CICS regions.
I think there’s more to it than just this PTF, something to do with the
vast number of tasks and task switches in the region.
APAR OA24094 In a CICS
Transaction Isolation Environment (ie. Using Subspaces) High Performance
Overhead In IAXVP Doing CSP.
The APAR description is:
In a CICS transaction isolation
environment (ie. subspaces are being utilized), very high performance overhead
occurs in IAXVP during CSP processing due to the private storage getmains
being done which drives page table initialization. The cause of the
high performance impact is the PTLB (purge translation lookaside buffers)
which occurs upon the CSP instruction. Note: This problem will
not be encountered if NOT running in a CICS transaction isolation environment
where subspaces are NOT utilized. [Ed. Note – Are there too many ‘NOT’s
in that last line?]
Ken would like to thank the respondents
on IBM Main who pointed him on the right track for this APAR.
-
Jerry Urbaniak from Acxiom pointed
out an IBM Red Alert that showed up on April 11, 2008:
A sysplex-wide outage can occur
when using CFRM MSGBASED processing after the fix for APAR OA21917 has
been applied.
APAR OA21917 (z/OA 1.7-1.9,
23Jan2008, HIPER) - ABEND00C RC13260001 IXCL2EVT Many Alter Begin/End
Events Stacked. PE.
APAR OA24563 (z/OS 1.7-1.9,
OPEN 21Apr2008) - ABEND00C RSN130E0001, ABEND00C RSN13260001, and/or
RC=10X From Parallel Sysplex Services.
See https://www14.software.ibm.com/webapp/set2/sas/f/redAlerts/
to get more information.
-
Another Red Alert showed up on Friday
(9May2008):
Sysplex-wide impact due to loop
in GRS on z/OS 1.9 and higher
In z/OS 1.9 and running in a GRS-Star
configuration, GRS recovery for GQSCAN retries with incorrect registers.
This can result in an ABEND0A0 followed by repetitive ABEND0C6 or ABEND0C4
in ISGQNX. As a result of the program check loop in ISGQNX's recovery,
no GRS work is able to run on the failing system. This may cause
sysplex-wide impact for the following reasons:
-
Global resources held by the failing
system cannot be released causing tasks that request the resources on other
systems to wait.
-
If the failing system is a GRS Lock
Manager, other systems may not be able to complete their XES requests.
-
Global GQSCANs may time out.
-
Global TEST ENQs cannot be processed.
-
No list ENQ requests can be processed
on other systems if the failing system is holding the GRS list lock.
Symptoms may also include:
-
High CPU usage in GRS and *MASTER*
on the failing system.
-
Message ISG361I indicating delays
on other systems in the Sysplex.
-
D GRS, C is unable to complete on
the problem system and Message ISG343I only returns local resource data
on other systems.
Please see APAR OA24741 (z/OS
1.9, 7May2008, HIPER, ISGQNX Recovery Recursively Suffers ABEND0C6) for
further details.
-
MXG Release 25.25 is important for sites
going to z/OS 1.9. There have been reported problems with going to
z/OS 1.9 without this yearly renewal. An even better release for
z/OS 1.9 is MXG Release 26.01. Plus, as usual, there are some really
neat new features in the latest MXG releases. See www.mxg.com.
-
Scott Barry of SBBWorks reports
that a z10 customer experienced problems when turning on HiperDispatch.
The problem has to do with floating point arithmetic, and can occur in
any program that does a lot of floating point. I’ve heard that it
has shown up in both SyncSort and SAS. The problem isn’t in the vendor
products, it’s in the floating point arithmetic logic. So please
don’t consider turning on HiperDispatch until you have applied the fix
for this APAR.
OA24322 (z/OS 1.7-1.9, HIPER,
18Mar2008) - Floating Point Regs Corrupted When Running With HiperDispatch
on D/T 2097. When running with HiperDispatch=ON, if a job that
uses floating point arithmetic gets interrupted by an SRM timer pop, the
floating point registers may be corrupted because IRABABAL does not save
or restore floating point registers. This can result in incorrect
output for the job that was interrupted.
2. Request for SMF Information
In our last Cheryl’s List, I sent
out the following request:
When discussing the new SMF logger
function at SHARE, we realized that nobody seems to have a good idea of
what volume of SMF data is being used these days. So at my 'Hot Flashes'
session, I asked people to email or fax me a copy of any output from IFASMFDP
(which shows types of records, number of records, record size, and interval).
This can simply be the output from your normal run, or if you want to make
a separate run, you could use either a full day or peak hours.
I'd appreciate any and all input,
and will publish my findings in a later Cheryl's List. All materials
will be kept confidential.
At least 50 people responded, and I
really appreciate the information. To answer the question about the
volumes, most people are collecting SMF data at less than 1MB/second, while
a few are collecting up to about 3MB/second. But the reports are
also showing me a lot of interesting things (such as those people who turn
on DB2 records are seeing over 80% of all SMF being created by DB2!), and
I’d like to share the findings. But I’d also like information from
even more installations before I complete my analysis. So if you
haven’t sent in your SMF reports, I’m still looking for more data.
Most of the reports I’ve received are for 24-hour periods. But, I’m
really interested to see the ratio between peak rates and 24-hour rates,
so if you have a chance to send both, I would be very excited. (And
those people who have been kind enough to send the 24-hour summaries, it
would be neat to see your peak periods too.)
One more request while I’m asking.
Would you also send me a copy of your SMFPRMxx member of IEASYSxx (or output
from console command ‘d smf,o’)? There are some things that I can’t
deduce from the dump listing. If you’ve already sent me the report
output, just a listing of your parms would be terrific. I think you’ll
all be interested in the results.
3. Status of Tuning Letter 2008 No. 2
I’m still working on the next issue
of the newsletter, but it’s taking me a little longer than usual.
As many of you know, I’ve had some back problems and they’ve been causing
me some grief. My instructions are not to sit for more than ten minutes
at a time. Can you imagine how disruptive that can be? Anyway,
I expect the issue to be out soon. The main topics in this issue
are: SMF Update – Part 1 (buffers, intervals, SMF logger); a new
‘Back to the Basics’ continuing column for those new to z/OS; an analysis
of z10 processors; z/OS 1.9 Performance; a SHARE Trip Report; and lots
and lots of interesting APARs and links. I’m sure that you’ll like
it.
Thanks for your continued patience
and support.
Stay Tuned!
Cheryl Watson
======================================================
Thanks for subscribing to Cheryl's
List!
Please note that this email service
is not intended to match or even summarize the large scope and volume of
information we provide in Cheryl Watson’s Tuning Letter. The
Tuning Letter is published six times a year and costs $865 (2008) for the
electronic version: a yearly CD-ROM of all back issues and six PDF issues
emailed during the year. See http://www.watsonwalker.com/TUNING.html
for details. Past tables of contents are at http://www.watsonwalker.com/TofC.html,
and some FULL SAMPLE ISSUES can be found at http://www.watsonwalker.com/sampleissues.html.
Single issues may be obtained for $155.
If you obtained this from someone
else and would like your own copy in the future, just go to our Web page
at http://www.watsonwalker.com
and fill out the form under "Cheryl's List." That signs you up, and
it's free! It's a one-way list, from us to you. If you make
a "reply," it will come just to us, not to the other members of the list.
We never share your address or information with anyone else. To unsubscribe
or change your email address, use the Web page and password mentioned in
your welcome message. Or, you can send an email request to admin
(at) watsonwalker.com. Past Cheryl's List issues, starting with
issue #1 from December of 1996 can be obtained at http://www.watsonwalker.com/archives.html.
In Cheryl's List, we provide updates
to our full newsletter, Cheryl Watson's Tuning Letter. We’ll also
let you know if anything of importance has been added to our Web pages,
and tell you about our other products and services, including BoxScore
and GoalTender.
So - we hope you'll find this service
valuable. Be sure to send email to technical (at) watsonwalker.com
if you have any questions or comments.
To the Top
|